CM12
COMMAND CODE
12
MAT
3.
ASSIGNMENT PROCEDURE:
ST + 12YY + DE +
4.
DATA TABLE:
YY
No.
MEANING
00
DTMF or DP
(PB/DP)
(This data setting is not
required for a Multiline
Terminal)
01
Trunk Restriction
(RSCA
Class
RSCB)
02
Service Restriction Class
(SFCA
A•B
SFCB)
CHAPTER 3
Page 100
Revision 2.0
TITLE:
STATION CLASS-1
Automatic/
STATION
Manual/
No.
Dial Intercom
(1-4 digits)
No. (4 digits)
DATA
1
2
3
XX
11
XXXX
1515
ND-45669 (E)
ICI/OPR
Loop
Line No.
Line No.
(4 digits)
(4 digits)
SETTING DATA
DP
DTMF
DP / DTMF
X
X
Night Trunk Restriction Class
Day Trunk Restriction Class
Contents of Day/Night Trunk Restriction Class
1: Unrestricted (RCA)
2: Non-Restricted 1 (RCB)
3: Non-Restricted 2 (RCC)
4: Semi-Restricted 1 (RCD)
5: Semi-Restricted 2 (RCE)
6: Restricted 1 (RCF)
7: Restricted 2 (RCG)
8: Fully-Restricted (RCH)
XX
XX
Service Restriction Class B
(00-15)
Service Restriction Class A
(00-15)
Note: The features available in each class are
programmed in CM15 YY = 00-49, YY = 53-73.
DATA
+ DE +
(1-4 digits)
:
MEANING
Restriction of
Connection Trunk:
CM35
YY=51-58
YY=61-68
Toll Restriction:
CM81, CM8A
+ EXE
Initial Data