COMMAND CODE
10
MAT
4.
DATA TABLE:
SETTING DATA (STATION NUMBER, TRUNK NUMBER, CARD NUMBER)
LEN
DATA
0000
x
xx
0511
xxx
xxxx
C100
C163
D000
D255
DA00
DA09
DB00
E000
E007
E100
E131
E200
E215
TITLE:
STATION NUMBER, TRUNK NUMBER, CARD NUMBER
MEANING OF DATA
Single Line Station Number (1-4 digits) x=0-9, A (*), B (#)
Note: When assigning a 5-digits station, assign the last four digits in
CM10.
Card number of AMP Trunk (PN-2AMPA)
When installed in PIM 0/1 . . . . .C100-C115
When installed in PIM 2/3 . . . . .C116-C131
When installed in PIM 4/5 . . . . .C132-C147
When installed in PIM 6/7 . . . . .C148-C163
(Maximum of 16 circuits per FP, 64 circuits per system.
Trunk Number (C.O./Tie Line, Paging, Radio Paging)
• For 4COT. . . 64 circuits (maximum) per PIM
• For 2COT/2ODT/AUC . . . 32 circuits (maximum) per PIM
• For TNT (BGM) . . . 10 circuits (maximum) per system
Circuit Number of External Hold Tone Interface (0-9) for Music On Hold
(PN-TNTA/PN-4COT)
Card Number for Interface of an External Announcement Machine for
Wake-Up Service
ATTCON Number (0-7)
DSS Console Number (00-31)
When installed in PIM 0/1 . . . . .E100-E107
When installed in PIM 2/3 . . . . .E108-E115
When installed in PIM 4/5 . . . . .E116-E123
When installed in PIM 6/7 . . . . .E124-E131
Note: The same number (the last two digits of the data) should not be
used, for both a DSS Console and Add-On Module.
Card Number of DTMF Receiver (PN-8RST A)
When installed in PIM 0/1 . . . . .E200-E203
When installed in PIM 2/3 . . . . .E204-E207
When installed in PIM 4/5 . . . . .E208-E211
When installed in PIM 6/7 . . . . .E212-E215
(Maximum of 32 DTMF Receivers [8 cards] can be assigned within a sys-
tem).
ND-45669 (E)
RELATED
COMMAND
CM38
CM30
CM44
CM48
CM44
CM48
CM90
CM60
CM96
CM97
CM45
INITIAL
Y = 0, 1
CHAPTER 3
Revision 2.0
CM10
Page 91