After Sales
Technical Documentation
3.3 – Call Simulation
3.3.1 – TX Power Level
All power levels (GSM: 5...15 PCN: 0...10) can be selected. This updates
the same parameter as TX Power Level in the RF Controls menu.
Note that TEST value cannot be selected. If TEST value was in use when Call simulation
menu was selected, power level is changed to the smallest value.
3.3.2 – Channel
This displays the normal operating RF channel number. Normal GSM
channel numbers can be selected. The same channel is used both for
transmission and receiving, this updates the same parameter as Channel
in the RF Controls menu.
3.3.3 – Monitoring Channels
Channels for monitoring are specified with these six selections. All GSM
channel numbers can be used. If more than one selection has the same
number, the monitoring channel list (neighbour list) will have less than 6
selected channels. The minimum number of monitoring channels is one
(all channels have the same value). The monitoring channel can also have
same value as a normal operating channel. The first monitoring channel
updates the same parameter as Monitoring Channel in the RF Controls
menu.
Amendment 1 04/97
RAE/RAK–1N
Service Software
Page 7– 33