After Sales
Technical Documentation
3.2.2 – TX Power Tuning
Once selected the display asks the following:
If <Y> is selected, tuning values from EEPROM are loaded. If <N> is
selected, the values which the PC program normally uses when DSP is
controlled are used. ESC returns to the previous menu. PC program
values are tuning settings which are used for DSP control in the local
mode.
GSM Version
PCN Version
Amendment 1 04/97
Note: Base Power level activated unless
command is interrupted by ESC
Do you want to load Values from EEPROM?
(Y/N) _
RAE/RAK–1N
Service Software
700