Setting Measurement Conditions

3-2 Shared settings

[1] Window shape selection and settings

This section describes how to select and set the
window shapes used for image processing (e.g.
rectangular windows, horizontal or vertical line
boundaries, circle windows, elliptical windows, and
polygonal windows). This can be done using the up,
3
down, left, and right setting keys on the remote key
pad.
(1) Rectangular window
Line type
Solid lines
Dotted lines
Image processing used
Positional deviation measurement (gray scale search), degree
Reference image for gray
of match inspection, lead inspection, multiple position
scale search and binary
measurement (gray scale search), and multiple degree of match
image matching
inspection.
Area measurement by binary conversion, object counting by
Window containing a
binary conversion, object identification by binary conversion.
binary image
Positional deviation measurement (gray scale search), degree
Gray scale search area
of match inspection, lead inspection (criteria search), multiple
position measurement (gray scale search) and multiple degree
detection
of match inspection.
Positional deviation measurement (edge detection), multiple
Edge of an area detection
position measurement (edge detection).
Area measurement by binary conversion, object counting by
Binary image window
binary conversion, object identification by binary conversion.
mask
EX: Register conditions of "Positional deviation
measurement."
REG COND SCREEN COND SAVE DETAIL
1REGISTER NO
0(0~7)
2MEAS SHAPE (MDL0) RECTANGLE
3REFIMG ARE (MDL0) SET
4SEARCH ARE (MDL0) SET
Measurement programs
3-4
F C1 BRT
(224,208)~(287,271)
(216,200)~(295,279)
RECTANGLE
X-LINE
Y-LINE

Hide quick links: