Sharp IV-S30J User Manual page 180

Compact image sensor camera
Table of Contents

Advertisement

Numerical Calculations
Setting details
The setting details and procedures for numerical calculations are the same for all measurement
programs with the exception of the point measurement program. In this section we explain the use of
the numerical calculations menu [NUMERIC CALC] for positional measurements.
"CHG-CALC"
Move the cursor to the "CHG-CALC" item.
Each time you press the SET key the display
in the left most column will alternate between
"AN00 to AN07" and "AN08 to AN15."
RUN A TEST
Pressing the SET key will store the setting
details as well as run a test
The numerical results of the tests will be
displayed at position [F] and the OK or NG
judgment will be displayed at position [E].
A: TYPE
Select the type of data being calculated.
The details displayed for each measuring
program.
See page 14-5 to 14-8.
B: FORMULA
Select the formula to apply. Select formula using the left and right arrow keys and enter
numerical values using the up and down arrow keys.
The details displayed for "FORMULA" will depend on the "TYPE" selected.
CRD-X, CRD-Y, DEV-x, DEV-y,
MATCH M, ANGL B
NUM-CAL [NC]
CNST [C]
For details about the items that can be selected with other measurement programs, see
pages 14-5 to 14-8.
C: UPR&LOW LIMIT
Enter the upper and lower limits for making a judgment.
14
D: OUTPUT
Setting the output of the calculation results. Select an output target: "NO," "Y," or "C."
The output can be set to Y0 to Y7 or C000 to C107.
- The number of styles may be set as follows, depending on the selections made in items A and
B.
OBJECT TYPE
NUM-CAL [NC]
The numbers from 00 to 07 in front of the characters are registration
Item selections
00X0 to 07X0 / 00Y0 to 07Y0
CRD [X Y]
0x0 to 7x0 / 0y0 to 7y0
DEV [x y]
00M0 to 07M0
MATCH [M]
ANGL [B]
CNST [C]
- [NUMERIC CALC] screen on positional deviation
measurement
NUMERIC CALC SCREEN COND SAVE
[N00-N07]
CHG-CALC
1RUN A TEST
TYPE
CRD-X
CRD-Y
DEV-x
DEV-y
MATCH M
ANGL-B
NUM-CAL[NC]
CNST[C]
NO
SET=EXEC ESC=BACK SEL=CHNG IMG TRG=FUNC
OBJECT TYPE, CALC RESULT, CNST, SUM, AVG, CBP,
CBM, DEL
ABS, SQRT, TAN, ATAN, MAX, MIN, DEL
+0000000.0000 (second line is not displayed)
Model 0
00X1 to 07X1 / 00Y1 to 07Y1
0x1 to 7x1 / 0y1 to 7y1
0B to 7B
ABS / SQRT / TAN / ATAN (00 to 14)
MAX/MIN (00 to 14)
-9999999.9999 to +9999999.9999
14-2
(SET KEY)
FORMULA
OBJECT TYPE
CALC RESULT
CNST
SUM
AVG
CBP
CBM
DEL
Selection on line
Model 1
Corresponds to
page 14-4.
00M1 to 07M1
These are the
same as for the
other
measurement
programs.
F C1 BRT

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents