(6) Degree of match inspection
Press the TRG/BRT key, and the will calculate the X-Y coordinates of the detection points in images 0
and 1, and then evaluate and output the results.
(TYPE00)
OK
MEAS XXXXms
MEASUREMENT 1 CHK-DEG-MATCH
REGISTER N00(0~15)
M0=+09735
OK
X0= 090.0
OK
Y0= 092.0
OK
G0= 018.0
OK
MNU-CHG MAIN-COND CHG-MEA COND-CHG CHNG-REG SCREEN-CHG CHG-TYPE
If the difference in the X and Y coordinates is within the range set on the numeric
calculation menu, Y0 will be turned ON, and a filled box
difference is not within the range, Y0 will be turned OFF, and an empty box
displayed.
Output conditions
Final output conditions
F C1 BRT
V*.**
14-15
Numerical Calculations
will be displayed. If the
will be
- If the result is within the range,
N00 and N01 will be turned ON
(OK), the auxiliary relay C000
will be turned ON, and output
Y00 will be turned ON.