Yamaha DME64N Owner's Manual page 430

Dme designer
Hide thumbs Also See for DME64N:
Table of Contents

Advertisement

Chapter 6 Component Guide
Crossover
Click the Speaker Processor [Crossover] button to open the crossover editor window.
1
2
1
2
3
4
5
6
430
DME Designer Owner's Manual
[Speaker Processor - Crossover] editor window
3
7
4
8
9
5
6
Section
Parameter
Polarity
Mute
Frequency
LPF
Type
Frequency
Gc
Range
Normal/Inverted
Inverts the polarity of each output channel.
ON/OFF
Mutes the output of each output channel.
This parameter is linked to the Mute setting in
the original window.
20 Hz to 20 kHz
Sets the crossover frequency between output
channels.
The display appears as a dotted line when
muted.
Thru
Sets the roll-off slope and filter type for each
6dB/Oct
octave.
12dB/Oct AdjustGc
The filter is bypassed when [Thru] is
12dB/Oct Butrwrth
selected.
12dB/Oct Bessel
12dB/Oct Linkwitz
18dB/Oct AdjustGc
18dB/Oct Butrwrth
18dB/Oct Bessel
24dB/Oct AdjustGc
24dB/Oct Butrwrth
24dB/Oct Bessel
24dB/Oct Linkwitz
36dB/Oct AdjustGc
36dB/Oct Butrwrth
36dB/Oct Bessel
48dB/Oct AdjustGc
48dB/Oct Butrwrth
48dB/Oct Bessel
48dB/Oct Linkwitz
20 Hz to 20 kHz
Sets the LPF cutoff frequency.
-6 dB to +6 dB
Sets the cutoff frequency gain when the
[Type] setting is [AdjustGc] (Adjustable Gc).
Function