5.3.5 Securing the ESS

Step 1 Open the door of the control unit cabin to get the angle steels in the carton.
Secure the ESS using four angle steels.
Issue 15 (2023-11-01)
Figure 5-6 Installing ground cables
Connect ground lugs to the ESS ground points using M12x30 stainless steel
bolt assemblies.
NO TE
– Ground lug: Use ground lugs made of hot-dip zinc-coated flat steel sheet with a
cross-sectional area of 40 mm x 4 mm, and leave 300 mm of each ground lug out
of the concrete platform (same as the height between the foundation and the
ground).
– Before the installation, remove the tinfoil from the ground lugs.
Figure 5-7 Installing ground lugs