2. Disconnect the left UV lamp connector by pressing in the two tabs on either side and pull it out.
Disconnect the right connector in the same way.
3. Hold the wire attached to the left end of the lamp in one hand and use a finger of the other hand
to reach under the ceramic end to ease the bulb out of the retainer clip. Perform the same action
to release the other end of the bulb.
Note the orientation of the ceramic end in the retainer clip so that you can put the new lamp in
the same spot. The clip clamps to the small diameter ceramic section at the end of the bulb.
How to Change a UV Lamp Bulb
Chapter 9 - Printer Maintenance