11.1 Installation Clearance Requirements

In an indoor scenario with DC power supply, a BBU and DCDU-03B can be installed on a wall.
In this case, the DCDU-03B supplies power to the BBU.
Installation Clearance Requirements for a Separate Wall-Mounted BBU
Figure 11-1
Figure 11-1 Installation clearance requirements for a separate wall-mounted BBU
Installation Clearance Requirements for a Wall-Mounted BBU and DCDU-03B
If a BBU and DCDU-03B are installed on a wall, a minimum of 100 mm between them must
be reserved for maintenance, as shown in
Issue 06 (2011-09-15)
shows the installation clearance requirements for a separate wall-mounted BBU.
NOTE
l A minimum of 600 mm in front of the BBU is reserved for maintenance.
l A minimum of 20 mm above the BBU is reserved for maintenance.
l A minimum of 800 mm below the BBU is reserved for maintenance.
l A minimum of 50 mm on the left or right of the BBU is respectively reserved for maintenance.
NOTE
A DCDU-03B must be installed close to a BBU.