Installing A Cpri Optical Cable - Huawei DBS3900 Installation Manual

Hide thumbs Also See for DBS3900:
Table of Contents

Advertisement

DBS3900 (Ver.B)
Installation Guide
Figure 9-29 Installing a monitoring signal cable between the HEUA and the BBU
Step 2 Route the cable by referring to
cable.
Step 3 Label the installed cables. For details, see Attaching an L-Shaped Label.
----End

9.4.7 Installing a CPRI Optical Cable

A CPRI optical cable transmits CPRI signals between a BBU and an RRU.
Context
l
l
l
The performance of an optical module that is exposed to the air for more than 20 minutes may
be abnormal. Therefore, you must insert an fiber optic cable into an unpacked optical module
within 20 minutes.
Issue 06 (2011-09-15)
The single-mode optical module is labeled "SM" and multi-mode optical module is labeled
"MM".
If the puller of an optical module is blue, the module is a single-mode optical module. If
the puller of an optical module is black or grey, the module is a multi-mode optical module.
The optical module to be installed must have a matching rate with the corresponding CPRI
port.
CAUTION
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
9 Outdoor Scenario with DC Power Supply (BBU Installed
9.4.1 Cabling
Requirements, and then use cable ties to bind the
in an OMB)
316