Belt Maintenance

Checking the
Alternator-Belt Tension
Service Interval: Every 100 hours
1.
Apply 44 N (10 lb) of force to the alternator belt,
midway between the pulleys.
2.
If the deflection is not 10 mm (3/8 inch), loosen
the alternator mounting bolts
Figure 45
1. Mounting bolt
3.
Increase or decrease the alternator-belt tension.
4.
Tighten the mounting bolts.
5.
Check the deflection of the belt again to ensure
that the tension is correct.
(Figure
45).
g008932
2. Alternator
Controls System
Maintenance
Adjusting the Control-Lever
Neutral-Interlock Switch
1.
Stop the machine, move the motion-control
levers to the N
parking brake, and remove the ignition key.
2.
Remove the bolts securing the front panel and
remove the panel
1. Bolt
2. Control panel
3.
Loosen the 2 screws securing the interlock
switch
(Figure
45
-
position, engage the
EUTRAL
LOCK
(Figure
46).
Figure 46
47).
g020875