OCR Type A230
Output control function
Use this when there are calculation result registers (with numerical values and judgment
results) that you do not want to output using parallel or serial communications.
Refer to page 13 − 16, Setting and Canceling Output Control.
Example:
1
CA01 = X direction distance
CA02 = Y direction distance
CA03 = angle calculated using CA01 and CA02
When using several formulas to calculate the final result (an
angle in the case above), you can use this function to output
the final result only.
Example:
2
XCA01 = X direction distance ← output suppressed
XCA02 = Y direction distance ← output suppressed
CA03 = angle calculated using CA01 and CA02
When output control is set for CA01 and CA02, only the CA03
result is externally output.
Inspection Results and Output
13.3 Numerical Calculation
13 − 9