Toro MMX-650E-S Operator's Manual page 18

Hide thumbs Also See for MMX-650E-S:
Table of Contents

Advertisement

plug. If it still does not fit, contact a qualified electrician to
install the proper outlet. Do not change the machine plug or
extension-cord plug in any way.
Note: The machine uses a twist-locking plug.
Extension Cords
Length
15.2 m (50 ft)
22.8 m (75 ft)
30.4 m (100 ft)
Note: Do not use an extension cord over 30.4 m (100 ft)
long.
Wire Gauge
10 AWG
10 AWG
8 AWG
Powering the Machine with a Portable
Generator
When using a portable generator as an electrical source,
ensure the following power output specifications:
Model
Voltage
68012
115 V /
230 V
68018
115 V /
230 V
68019
115 V /
230 V
Resetting the Motor
The electrical motor for the machine is equipped with a
device for thermal-overload protection. In the event that the
motor shuts down automatically, reset the thermal-overload
protector as follows:
1. Move the O
/O
N
to
Figure
12.
2. Disconnect the electrical plug for the machine from the
power source
(Figure
1. Thermal-overload
protector reset button
2. O
/O
switch
N
FF
3. Allow the electric motor of the machine to cool until it
is warm to the touch or cooler.
Important: Ensure that the paddles spin freely.
Check for stone, masonry, or concrete material
between the paddles and the drum.
18
Amperes
Kilowatt
hour
19 A /
2.2 to 2.3
Kw
9.5 A
19 A /
2.2 to 2.3
9.5 A
Kw
24 A /
2.2 to 2.3
12 A
Kw
switch to the O
position; refer
FF
FF
25).
Figure 25
3. Electrical plug
Frequency/
phase
60 Hz /
single
60 Hz /
single
60 Hz /
single

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mmx-850e-s60212. 6021860219

Table of Contents