Shielding E1/T1 Cables - Huawei Airbridge BTS3606 Installation Manual

Cdma base station cabinet installation
Hide thumbs Also See for Airbridge BTS3606:
Table of Contents

Advertisement

Installation Manual – BTS3606A Cabinet Installation
Airbridge BTS3606&3606A CDMA Base Station
7)
Insert one half of the module from the bottom of the cabinet. Press the cable
against the module and insert the other half of the module and press them with
hands.
Figure 5-29 Installing the cable
8)
Install other cables and sealing modules in sequence.
If the last module cannot be inserted to its position easily, press tight the modules
installed already and try again.
9)
Select a smaller module for pre-pressing.
Generally, the medium module is finally used according to the installation rule.
10) Insert the small module to the installation position. Lubricate the subrack if it is
hard to insert the last module.
11) Use a wrench to fasten the nut to the fastener as tight as possible.
12) Unscrew the nut 10 to 15 minutes later.
13) Take out the small module, and insert the sealing module to be installed.
14) Fasten the nut of the fastener again.