Mitsubishi Electric A800 Instruction Manual page 63

Hide thumbs Also See for A800:
Table of Contents

Advertisement

Rating
400 V class
Model FR-A840-[ ]
SLD
Applicable motor
LD
capacity (kW)

ND (initial setting)
HD
SLD
Rated
LD
capacity
ND (initial setting)
(kVA)

HD
SLD
LD
Rated current
(A)
ND (initial setting)
HD
SLD
Overload
LD
current rating
ND (initial setting)

HD
Rated voltage

Brake transistor
Maximum brake torque
Regenerative
FR-ABR
braking
(when the option is
used)
Rated input
AC voltage/frequency
Permissible AC voltage fluctuation
Permissible frequency fluctuation
SLD
LD
Rated input
current (A)

ND (initial setting)
HD
SLD
Power supply
LD
capacity
ND (initial setting)
(kVA)

HD
Protective structure (IEC 60529)

Cooling system
Approx. mass (kg)

The applicable motor capacity indicated is the maximum capacity applicable for use of the Mitsubishi 4-pole standard motor.

The 0.2 kW motor capacity is applicable under V/F control only.

The rated output capacity indicated assumes that the output voltage is 440 V for 400 V class.

The % value of the overload current rating indicated is the ratio of the overload current to the inverter's rated output current. For repeated duty, allow time for the inverter
and motor to return to or below the temperatures under 100% load.

The maximum output voltage does not exceed the power supply voltage. The maximum output voltage can be changed within the setting range. However, the maximum
point of the voltage waveform at the inverter output side is the power supply voltage multiplied by about

Value for the built-in brake resistor

Value for the ND rating

The rated input current indicates a value at a rated output voltage. The impedance at the power supply side (including those of the input reactor and cables) affects the
rated input current.

The power supply capacity is the value when at the rated output current. It varies by the impedance at the power supply side (including those of the input reactor and
cables).

FR-DU08: IP40 (except for the PU connector section)

For the power voltage exceeding 480 V, set Pr.977 Input voltage mode selection. (For details, refer to the Instruction Manual (Detailed)).

The braking capability of the inverter built-in brake can be improved with a commercial brake resistor. For the details, please contact your sales representative.
26
SPECIFICATIONS
00023 00038 00052 00083 00126 00170 00250 00310 00380 00470 00620 00770 00930 01160 01800 02160 02600 03250 03610 04320 04810 05470 06100 06830
0.4K 0.75K 1.5K 2.2K 3.7K 5.5K 7.5K 11K 15K 18.5K 22K 30K 37K 45K 55K 75K 90K 110K 132K 160K 185K 220K 250K 280K
0.75 1.5
2.2
3.7
5.5
7.5
11
0.75 1.5
2.2
3.7
5.5
7.5
11
0.4
0.75 1.5
2.2
3.7
5.5
7.5
0.2
0.4
0.75 1.5
2.2
3.7
5.5

1.8
2.9
4
6.3
10
13
19
1.6
2.7
3.7
5.8
8.8
12
18
1.1
1.9
3
4.6
6.9
9.1
13
0.6
1.1
1.9
3
4.6
6.9
9.1
2.3
3.8
5.2
8.3
12.6 17
25
2.1
3.5
4.8
7.6
11.5 16
23
1.5
2.5
4
6
9
12
17
0.8
1.5
2.5
4
6
9
12
110% 60 s, 120% 3 s (inverse-time characteristics) at surrounding air temperature 40°C
120% 60 s, 150% 3 s (inverse-time characteristics) at surrounding air temperature 50°C
150% 60 s, 200% 3 s (inverse-time characteristics) at surrounding air temperature 50°C
200% 60 s, 250% 3 s (inverse-time characteristics) at surrounding air temperature 50°C
Three-phase 380 to 500 V
Built-in
100% torque/2%ED


100% torque/10%ED
Three-phase 380 to 500 V 50 Hz/60 Hz
323 to 550 V 50 Hz/60 Hz
±5%
3.2
5.4
7.8
10.9 16.4 22.5 31.7 40.3 48.2 58.4 76.8 97.6 115 141 180 216 260 325 361 432 481 547 610 683
3
4.9
7.3
10.1 15.1 22.3 31
2.3
3.7
6.2
8.3
12.3 17.4 22.5 31
1.4
2.3
3.7
6.2
8.3
12.3 17.4 22.5 31
2.5
4.1
5.9
8.3
12
17
24
2.3
3.7
5.5
7.7
12
17
24
1.7
2.8
4.7
6.3
9.4
13
17
1.1
1.7
2.8
4.7
6.3
9.4
13
Enclose type (IP20)
Self-cooling
Forced air cooling
2.8
2.8
2.8
3.3
3.3
6.7
6.7
15
18.5 22
30
37
45
55
15
18.5 22
30
37
45
55
11
15
18.5 22
30
37
45
7.5
11
15
18.5 22
30
37
24
29
36
47
59
71
88
22
27
33
43
53
65
81
18
24
29
34
43
54
66
13
18
24
29
34
43
54
31
38
47
62
77
93
116 180
29
35
43
57
70
85
106 144
23
31
38
44
57
71
86
17
23
31
38
44
57
71
20% torque/continuous
100% torque/6%ED


38.2 44.9 53.9 75.1 89.7 106 130 144 180 216 260 325 361 432 481 547 610
40.3 48.2 56.5 75.1 91
108 134 144 180 216 260 325 361 432 481 547
40.3 48.2 56.5 75.1 91
31
37
44
59
74
88
107 137 165 198 248 275 329 367 417 465 521
29
34
41
57
68
81
99
24
31
37
43
57
69
83
17
24
31
37
43
57
69
Open type (IP00)
8.3
8.3
15
15
23
41
41
75/
110 132 160 185 220 250 280 315 355
90
75
90
110 132 160 185 220 250 280 315
55
75
90
110 132 160 185 220 250 280
45
55
75
90
110 132 160 185 220 250
137 165 198 248 275 329 367 417 465 521
110 137 165 198 248 275 329 367 417 465
84
110 137 165 198 248 275 329 367 417
66
84
110 137 165 198 248 275 329 367
216
260
325
361
432
481
180
216
260
325
361
432
110
144
180
216
260
325
361
86
110
144
180
216
260
325
FR-BU2(Option)
10% torque/continuous
108 110 144 180 216 260 325 361 432 481
110 137 165 198 248 275 329 367 417 465
102 110 137 165 198 248 275 329 367 417
83
84
110 137 165 198 248 275 329 367
43
52
55
71
78
117 117 166 166 166
.
547
610
683
481
547
610
432
481
547
361
432
481

Hide quick links:

Advertisement

Chapters

Table of Contents
loading

Table of Contents