Mitsubishi Electric A800 Instruction Manual page 55

Hide thumbs Also See for A800:
Table of Contents

Advertisement

Parameter list
Pr.
Name
133
PID action set point
0 to 100%, 9999 9999
0.01 to 10s,
134
PID differential time
9999
Electronic bypass
135
0, 1
sequence selection
MC switchover interlock
136
0 to 100s
time
137
Start waiting time
0 to 100s
Bypass selection at a
138
0, 1
fault
Automatic switchover
139
frequency from inverter
0 to 60Hz, 9999 9999
to bypass operation
Backlash acceleration
140
0 to 590Hz
stopping frequency
Backlash acceleration
141
0 to 360s
stopping time
Backlash deceleration
142
0 to 590Hz
stopping frequency
Backlash deceleration
143
0 to 360s
stopping time
0, 2, 4, 6, 8, 10,
Speed setting
12, 102, 104,
144
switchover
106, 108, 110,
112
PU display language
145
0 to 7
selection
Acceleration/
147
deceleration time
0 to 590Hz, 9999
switching frequency
Stall prevention level at
148
0 to 400%
0 V input
Stall prevention level at
149
0 to 400%
10 V input
Output current
150
0 to 400%
detection level
Output current detection
151
0 to 10s
signal delay time
Zero current detection
152
0 to 400%
level
Zero current detection
153
0 to 10s
time
Voltage reduction
154
selection during stall
0, 1, 10, 11
prevention operation
RT signal function
155
validity condition
0, 10
selection
Stall prevention
156
0 to 31, 100, 101 0
operation selection
157
OL signal output timer
0 to 25s, 9999
1 to 3, 5 to 14,
17, 18, 21, 24,
AM terminal function
32 to 34, 36, 46,
158
selection
50, 52 to 54, 61,
62, 67, 70,
87 to 98
Automatic switchover
frequency range from
159
0 to 10Hz, 9999 9999
bypass to inverter
operation
160
User group read
0, 1, 9999
selection

Frequency setting/key
161
0, 1, 10, 11
lock operation selection
Automatic restart after
162
instantaneous power
0 to 3, 10 to 13 0
failure selection
First cushion time for
163
0 to 20s
restart
First cushion voltage for
164
0 to 100%
restart
Stall prevention
165
0 to 400%
operation level for restart
Output current
166
detection signal
0 to 10s, 9999
retention time
Output current
167
detection operation
0, 1, 10, 11
selection
168
Parameter for manufacturer setting. Do not set.
169
170
Watt-hour meter clear
0, 10, 9999
Operation hour meter
171
0, 9999
clear
User group registered
172
9999, (0 to 16)
display/batch clear
173
User group registration 0 to 1999, 9999
174
User group clear
0 to 1999, 9999
18
DRIVE THE MOTOR
Setting
Initial
Pr.
range
value
STF terminal function
178
selection
9999
STR terminal function
179
selection
0
RL terminal function
180
selection
1s
RM terminal function
181
selection
0.5s
RH terminal function
182
0
selection
RT terminal function
183
selection
AU terminal function
184
selection
1Hz
JOG terminal function
185
selection
0.5s
CS terminal function
186
selection
1Hz
MRS terminal function
187
selection
0.5s
STOP terminal function
188
selection
RES terminal function
4
189
selection
RUN terminal function
190
selection
SU terminal function
191
selection
9999
IPF terminal function
192
selection
150%
OL terminal function
193
selection
200%
FU terminal function
194
selection
150%
ABC1 terminal function
195
selection
0s
ABC2 terminal function
196
selection
5%
232 to
Multi-speed setting (8
239
speed to 15 speed)
0.5s
Soft-PWM operation
240
selection
Analog input display
1
241
unit switchover
Terminal 1 added
0
242
compensation amount
(terminal 2)
Terminal 1 added
243
compensation amount
(terminal 4)
0s
Cooling fan operation
244
selection
245
Rated slip
1
Slip compensation time
246
constant
Constant-power range slip
247
compensation selection
Self power
248
management selection
Earth (ground) fault
249
0
detection at start
0
250
Stop selection
Output phase loss
251
protection selection
252
Override bias
0s
253
Override gain
Main circuit power OFF
0%
254
waiting time
Life alarm status
150%
255
display
Inrush current limit
256
0.1s
circuit life display
Control circuit capacitor
257
life display
0
Main circuit capacitor
258
life display
Main circuit capacitor
259
life measuring
9999
PWM frequency
260
automatic switchover
9999
Power failure stop
261
selection
0
Subtracted frequency at
262
deceleration start
9999
Subtraction starting
9999
263
frequency
Power-failure
264
deceleration time 1
Power-failure
265
deceleration time 2
Power failure deceleration
266
time switchover frequency
Terminal 4 input
267
selection
Setting
Initial
Name
range
value
60
61
0
1
0 to 20,
2
22 to 28, 37,
42 to 48,
3
50 to 53,
60 to 62,
64 to 74,
4
76 to 80, 87,
92 to 96, 9999
5

6
24
25
62
0
0 to 8, 10 to 20, 22,
25 to 28, 30 to 36,
38 to 57, 60, 61, 63,
1
64, 67, 68, 70, 79,
84, 85, 90 to 99,
2
100 to 108,
110 to 116, 120,
122, 125 to 128,
3
130 to 136,
138 to 157, 160,
4
161, 163, 164, 167,
168, 170, 179, 184,
185, 190 to 199,
99
200 to 208,
300 to 308, 9999

9999
0 to 590Hz, 9999
9999
0, 1
1
0, 1
0
0 to 100%
100%
0 to 100%
75%
0, 1, 101 to 105
1
0 to 50%, 9999 9999
0.01 to 10s
0.5s
0, 9999
9999
0 to 2
0
0, 1
0
0 to 100s,
1000 to 1100s,
9999
8888, 9999
0, 1
1
0 to 200%
50%
0 to 200%
150%
0 to 3600s,
600s
9999
(0 to 15)
0
(0 to 100%)
100%
(0 to 100%)
100%
(0 to 100%)
100%
0, 1
0
0, 1
1
0 to 2, 11, 12,
0
21, 22
0 to 20Hz
3Hz
0 to 590Hz, 9999
60/50Hz
0 to 3600s
5s
0 to 3600s, 9999
9999
0 to 590Hz
60/50Hz
0 to 2
0
Pr.
Name
Monitor decimal digits
268
0, 1, 9999
selection
269
Parameter for manufacturer setting. Do not set.
Stop-on contact/load
270
torque high-speed
0 to 3, 11, 13
frequency control selection
High-speed setting
271
0 to 400%
maximum current
Middle-speed setting
272
0 to 400%
minimum current
Current averaging
273
0 to 590Hz, 9999
range
Current averaging filter
274
1 to 4000
time constant
Stop-on contact
275
excitation current low-
50 to 300%, 9999 9999
speed multiplying factor
0 to 9, 9999
PWM carrier frequency
276
at stop-on contact
0 to 4, 9999
Brake opening
278
0 to 30Hz
frequency
279
Brake opening current
0 to 400%
Brake opening current
280
0 to 2s
detection time
Brake operation time at
281
0 to 5s
start
Brake operation
282
0 to 30Hz
frequency
Brake operation time at
283
0 to 5s
stop
Deceleration detection
284
0, 1
function selection
Overspeed detection
285
frequency (Excessive speed
0 to 30Hz, 9999 9999
deviation detection frequency)
286
Droop gain
0 to 100%
287
Droop filter time constant 0 to 1s
Droop function
288
0 to 2, 10, 11
activation selection
Inverter output terminal
289
5 to 50ms, 9999 9999
filter
Monitor negative output
290
0 to 7
selection
0, 1, 10, 11, 20,
21, 100
291
Pulse train I/O selection
(FM type)
0, 1 (CA type)
Automatic acceleration/
292
0, 1, 3, 5 to 8, 11
deceleration
Acceleration/deceleration
293
0 to 2
separate selection
UV avoidance voltage
294
0 to 200%
gain
Frequency change
0, 0.01, 0.10,
295
increment amount
1.00, 10.00
setting
0 to 6, 99,
296
Password lock level
100 to 106, 199,
9999
(0 to 5),
297
Password lock/unlock
1000 to 9998,
9999
298
Frequency search gain 0 to 32767, 9999
Rotation direction detection
299
0, 1, 9999
selection at restarting
RS-485 communication
331
0 to 31(0 to 247)
station number
3, 6, 12, 24, 48,
RS-485 communication
332
96, 192, 384,
speed
576, 768, 1152
RS-485 communication
333
stop bit length / data
0, 1, 10, 11
length
RS-485 communication
334
0 to 2
parity check selection
RS-485 communication
335
0 to 10, 9999
retry count
RS-485 communication
0 to 999.8s,
336
check time interval
9999
RS-485 communication
337
0 to 150ms, 9999
waiting time setting
Communication
338
operation command
0, 1
source
Communication speed
339
0 to 2
command source
Communication startup
340
0 to 2, 10, 12
mode selection

RS-485 communication
341
0 to 2
CR/LF selection
Communication EEPROM
342
0, 1
write selection
Communication error
343
count

Stop position command
350
0, 1, 9999

selection
351
Orientation speed
0 to 30Hz

Setting
Initial
range
value
9999
0
50%
100%
9999
16

9999

3Hz
130%
0.3s
0.3s
6Hz
0.3s
0
0%
0.3s
0
0
0
0
0
100%
0
9999
9999
9999
0
0
96
1
2
1
0s
9999
0
0
0
1
0
0
9999
2Hz

Hide quick links:

Advertisement

Chapters

Table of Contents
loading

Table of Contents