Mitsubishi Electric A800 Instruction Manual page 58

Hide thumbs Also See for A800:
Table of Contents

Advertisement

Setting
Pr.
Name
range
Fall-time torque bias
848
0 to 400%, 9999
terminal 1 gain
Analog input offset
849
0 to 200%
adjustment
Brake operation
850
0 to 2
selection
Control terminal option-
851
Number of encoder
0 to 4096

pulses
Control terminal option-
852
Encoder rotation
0, 1, 100, 101

direction
853
Speed deviation time
0 to 100s

854
Excitation ratio
0 to 100%
Control terminal option-
855
Signal loss detection
0, 1
enable/disable

selection
Terminal 4 function
858
0, 1, 4, 9999
assignment
0 to 500A, 9999

Torque current/Rated
859
PM motor current
0 to 3600A,
9999

0 to 500A, 9999
Second motor torque

860
current/Rated PM
0 to 3600A,
motor current
9999

Encoder option
862
0, 1

selection
Control terminal option-
863
Encoder pulse division
1 to 32767

ratio
864
Torque detection
0 to 400%
865
Low speed detection
0 to 590Hz
Torque monitoring
866
0 to 400%
reference
867
AM output filter
0 to 5s
Terminal 1 function
868
0 to 6, 9999
assignment
869
Current output filter
0 to 5s

Speed detection
870
0 to 5Hz
hysteresis
Input phase loss
872
0, 1
protection selection
873
Speed limit
0 to 400Hz

874
OLT level setting
0 to 400%
875
Fault definition
0, 1
876
Thermal protector input 0, 1

Speed feed forward
877
control/model adaptive
0 to 2
speed control selection
Speed feed forward
878
0 to 1s
filter
Speed feed forward
879
0 to 400%
torque limit
880
Load inertia ratio
0 to 200 times
Speed feed forward
881
0 to 1000%
gain
Regeneration
882
avoidance operation
0 to 2
selection
Regeneration
883
avoidance operation
300 to 800V
level
Regeneration avoidance
884
at deceleration detection
0 to 5
sensitivity
Regeneration avoidance
885
compensation frequency
0 to 590Hz, 9999 6Hz
limit value
Regeneration
886
avoidance voltage gain 0 to 200%
888
Free parameter 1
0 to 9999
889
Free parameter 2
0 to 9999
Cumulative power
891
0 to 4, 9999
monitor digit shifted times
892
Load factor
30 to 150%
Energy saving monitor
0.1 to 55kW
893
reference (motor
0 to 3600kW
capacity)
Control selection during
894
commercial power-
0 to 3
supply operation
Power saving rate
895
0, 1, 9999
reference value
896
Power unit cost
0 to 500, 9999
Power saving monitor
0, 1 to 1000h,
897
average time
9999
Power saving cumulative
898
0, 1, 10, 9999
monitor clear
Operation time rate
899
0 to 100%, 9999 9999
(estimated value)
Initial
Pr.
Name
value
C0
FM/CA terminal
9999
(900)
calibration


C1
100%
AM terminal calibration ―
(901)

C2
Terminal 2 frequency
0
(902)
setting bias frequency

C3
Terminal 2 frequency
2048
(902)
setting bias

125
Terminal 2 frequency
(903)
setting gain frequency

1
C4
Terminal 2 frequency
(903)
setting gain

1s
C5
Terminal 4 frequency
100%
(904)
setting bias frequency

C6
Terminal 4 frequency
(904)
setting bias

0
126
Terminal 4 frequency
(905)
setting gain frequency

C7
Terminal 4 frequency
0
(905)
setting gain

C12
Terminal 1 bias
(917)
frequency (speed)

9999
C13
Terminal 1 bias (speed) 0 to 300%
(917)

C14
Terminal 1 gain
(918)
frequency (speed)

9999
C15
Terminal 1 gain (speed) 0 to 300%
(918)

C16
Terminal 1 bias
0
(919)
command (torque)

C17
Terminal 1 bias (torque) 0 to 300%
1
(919)

C18
Terminal 1 gain
150%
(920)
command (torque)

1.5Hz
C19
Terminal 1 gain (torque) 0 to 300%
(920)

150%
C8
Current output bias
0.01s
(930)
signal

0
C9
Current output bias
(930)
current

0.02s
C10
Current output gain
(931)
0Hz
signal

C11
Current output gain
0
(931)
current

20Hz
C38
Terminal 4 bias
(932)
command (torque)

150%
C39
Terminal 4 bias (torque) 0 to 300%
0
(932)

C40
Terminal 4 gain
1
(933)
command (torque)

C41
Terminal 4 gain (torque) 0 to 300%
0
(933)

C42
PID display bias
(934)
coefficient
0s

C43
PID display bias analog
(934)
value

150%
C44
PID display gain
7 times
(935)

coefficient
C45
PID display gain analog
0%
(935)
value

Input voltage mode
977
0
selection
Parameter copy alarm
989
DC380/
release
DC760V

990
PU buzzer control
991
PU contrast adjustment 0 to 63
0
Operation panel setting
992
dial push monitor
selection
100%
994
Droop break point gain 0.1 to 100%, 9999
9999
Droop break point
9999
995
torque
9999
997
Fault initiation
100%
PM parameter
998
initialization
Inverter

rated
Automatic parameter

capacity
999
setting
1000
Parameter for manufacturer setting. Do not set.
0
Lq tuning target current
1002
adjustment coefficient
9999
1003
Notch filter frequency
9999
1004
Notch filter depth
1005
Notch filter width
9999
1006
Clock (year)
9999
Setting
Initial
Pr.
range
value
0 to 590Hz
0Hz
1007
Clock (month, day)
0 to 300%
0%
0 to 590Hz
60/50Hz

0 to 300%
100%
0 to 590Hz
0Hz
0 to 300%
20%
0 to 590Hz
60/50Hz

0 to 300%
100%
1008
Clock (hour, minute)
0 to 590Hz
0Hz
0%
0 to 590Hz
60/50Hz

100%
0 to 400%
0%
Integral stop selection
1015
at limited frequency
0%
PTC thermistor
1016
protection detection time 0 to 60s
0 to 400%
150%
Monitor with sign
1018
selection
100%
1020
Trace operation selection 0 to 4
1021
Trace mode selection
0 to 100%
0%
1022
Sampling cycle
Number of analog
0 to 100%
0%
1023
channels
1024
Sampling auto start
0 to 100%
100%
1025
Trigger mode selection 0 to 4
Number of sampling
1026
before trigger
0 to 100%
100%
Analog source selection
1027
(1ch)
0 to 400%
0%
Analog source selection
1028
(2ch)
20%
Analog source selection
1029
(3ch)
0 to 400%
150%
Analog source selection
1030
(4ch)
100%
Analog source selection
1031
(5ch)
0 to 500.00,
9999
Analog source selection
9999
1032
(6ch)
0 to 300%
20%
Analog source selection
1033
(7ch)
0 to 500.00,
9999
Analog source selection
9999
1034
(8ch)
0 to 300%
100%
1035
Analog trigger channel 1 to 8
Analog trigger
1036
0, 1
0
operation selection
1037
Analog trigger level
10
10


Digital source selection
100
100


1038
(1ch)
0, 1
1
Digital source selection
58
1039
(2ch)
0 to 3, 5 to 14,
Digital source selection
17 to 20,
1040
(3ch)
22 to 36, 38,
40 to 46,
0
Digital source selection
1041
(4ch)
50 to 57, 61, 62,
64, 67, 71 to 74,
Digital source selection
1042
87 to 97, 100
(5ch)
9999
Digital source selection
1043
(6ch)
0.1 to 100%
100%
Digital source selection
1044
(7ch)
0 to 255, 9999
9999
Digital source selection
0, 3003, 3103,
1045
(8ch)
8009, 8109,
0
9009, 9109
1046
Digital trigger channel
1, 2,10 to 13,
Digital trigger operation
9999
1047
20, 21, 9999
selection
1048
Display-off waiting time
50 to 150%,
1049
USB host reset
9999
9999
DC brake judgment time
0, 8 to 1250Hz
0
1072
for swinging suppression
control operation
0 to 3
0
Swinging suppression
0 to 3
0
1073
control operation
2000 to 2099
2000
selection
Swinging suppression
1074
frequency
Swinging suppression
1075
depth
Parameter list
Setting
Initial
Name
range
value
101 to 131,
201 to 229,
301 to 331,
401 to 430,
501 to 531,
601 to 630,
101
701 to 731,
801 to 831,
901 to 930,
1001 to 1031,
1101 to 1130,
1201 to 1231
0 to 59, 100 to
159, 200 to 259,
300 to 359,
400 to 459,
500 to 559,
600 to 659,
700 to 759,
800 to 859,
900 to 959,
1000 to 1059,
1100 to 1159,
1200 to 1259,
0
1300 to 1359,
1400 to 1459,
1500 to 1559,
1600 to 1659,
1700 to 1759,
1800 to 1859,
1900 to 1959,
2000 to 2059,
2100 to 2159,
2200 to 2259,
2300 to 2359
0, 1, 10, 11
0
0s
0, 9999
9999
0
0 to 2
0
0 to 9
2
1 to 8
4
0, 1
0
0
0 to 100%
90%
201
202
1 to 3, 5 to 14,
17 to 20,
22 to 24,
203
32 to 36,
40 to 42, 46,
204
52 to 54, 61, 62,
64, 67, 71 to 74,
87 to 98,
205
201 to 213,
222 to 227,
206
230 to 238,
240 to 247
251 to 254
207
208
1
0, 1
0
600 to 1400
1000
1
2
3
4
1 to 255
5
6
7
8
1 to 8
1
0, 1
0
0 to 60m
0m
0, 1
0
0 to 10s
3s
0, 1
0
0.05 to 3Hz,
1Hz
9999
0 to 3
0
21
DRIVE THE MOTOR

Hide quick links:

Advertisement

Chapters

Table of Contents
loading

Table of Contents