GE DigitalFlow XGS868i Programming Manual page 90

Panametrics steam ultrasonic mass flow transmitter
Table of Contents

Advertisement

CH1
SLOT0
Slot 0 Outputs
A
B
Slot 0 Output A
Off
0-20m
4-20m
Channel
(appears only for 2-Channel meter)
CH1
CH2
SUM
DIF
Measurement Name
VEL
VOLUM
+TOTL
–TOTL
TIME
MDOT
SS up
T up
+MASS
–MASS
SS do
SNDSP
Qup
Tdown
DELTA
REYN#
Tot K
PEAK%
Qdown
AMPup
AMPdn
CNTup
CNTdn
P#up
P#dn
TEMP
PRESR
Z
AcVOL
StVOL
Tsupr
Vinst
Tsat
Rho
Kelvn
kPa
NOTE: Plain text represents prompt area messages and
boxed text represents option bar choices.
Fx represent function keys to select option bar choices.
DigitalFlow™ XGS868i Programming Manual
[Esc]
[Enter]
[Esc]
Keypad Pgm.
PROG
(* for 2-Channel meter only)
CH2*
GLOBL
See Figures 28 and 29
SYSTM
I/O
See Figure 30
Error Handling
See Figure 30
Analog Outputs
AVE
A
B
Slot 1 Outputs
Off
0-20m
4-20m
Channel
(appears only for 2-Channel meter)
CH1
CH2
SUM
DIF
AVE
QUAL
Measurement Name
VEL
VOLUM
+TOTL
–TOTL
TIME
MDOT
T up
+MASS
–MASS
SS up
SS do
SNDSP
Tdown
DELTA
REYN#
Tot K
PEAK%
Qup
AMPup
CNTup
P#up
Qdown
AMPdn
CNTdn
P#dn
TEMP
PRESR
Z
AcVOL
StVOL
Vinst
Tsat
Tsupr
Rho
Kelvn
kPa
QUAL
ZERO
FULL
RESET
CALIB
Reset Totals
See Service Manual
DARKN
NO
YES
STORE
COMM
SECUR
See Figure 30
See Figure 30
Options
Display
See Figure 30
I/O (appears only if option card is installed)
SLOT1
Totalizer Outputs
Frequency Outputs
A
B
C
D
Slot 1 Outputs
OFF
TTLZR
Channel
(appears only for 2-Channel meter)
CH1
CH1
CH2
SUM
DIF
AVE
Measurement Name
VEL
VOLUM
+TOTL
–TOTL
+MASS
–MASS
+MASS
–MASS
MINIMUM ON
Tdown
DELTA
UNITS/PULSE
PULSE TIME
Qdown
AMPup
RTD Inputs
P#dn
TEMP
A
B
C
D
Vinst
LABEL
Input measurement
FULL SCALE FREQUENCY
OFF
TEMP
Low
High
Input measurement
FULL Scale Value
CNTRS
LITEN
ABORT
Alarm Relays
A
B
C
D
A
B
Slot 1 Outputs
Slot 1 Outputs
OFF
FREQ
OFF
HIGH
Channel
(appears only for 2-Channel meter)
CH2
SUM
DIF
AVE
Measurement Name
+TOTL
–TOTL
TIME
MDOT
Channel (appears only for 2-Channel meter)
SS up
T up
SS do
SNDSP
CH1
CH2
Qup
REYN#
Tot K
PEAK%
AMPdn
CNTup
CNTdn
P#up
PRESR
Z
AcVOL
StVOL
Tsat
Tsupr
Rho
Kelvn
kPa
QUAL
BASE
HIGH/LOW
FULL
VEL
VOLUM
+TOTL
Analog Inputs
+MASS
–MASS
SS up
A
B
C
D
Tdown
DELTA
REYN#
LABEL
Qdown
AMPup
AMPdn
P#dn
TEMP
PRESR
OFF
PRESR
TEMP
SPEC
INPUT NAME
Tsupr
Vinst
Tsat
INPUT UNITS
ZERO Value
Trigger point
Appendix A. Menu Maps
C
D
LOW
FAULT
Failsafe?
NO
YES
SUM
DIF
AVE
FAULT
Fault Type
FLOW
OTHER
ALL
Measurement Name
–TOTL
TIME
MDOT
SS do
SNDSP
T up
Tot K
PEAK%
Qup
CNTup
CNTdn
P#up
Z
AcVOL
StVOL
Rho
Kelvn
kPa
QUAL
(All diagnostic parameters
appear here.)
80