1.9.2g Totalizer Outputs (cont.)
Setting Up the Totalizer
1. Scroll to the desired Channel option and press [Enter].
2. Scroll to the desired Measurement parameter and press [Enter]. See Table 10 below for a list of the available
options.
Note: The measurement units that appear in these prompts are those selected in the
this section.
3. Use the arrow keys to enter a value for the minimum Pulse On time (between 1 sec and 10,000 sec) for the
frequency of the totalizer pulses and press [Enter].
Note: A complete pulse consists of equal amounts of ON and OFF times. Choose a value that is compatible with the
frequency counter to be used.
4. Use the arrow keys to enter a value for the number of measurement units represented by each pulse and press
[Enter].
Procedure Options
After completing the above steps, the XGS868i returns to the I/O window. Do one of the following:
•
To continue programming, refer to Appendix A, Menu Maps, to navigate to the desired menu.
To leave the Keypad Program, press [Escape] four times.
•
DigitalFlow™ XGS868i Programming Manual
Table 10: Output Measurement Options
Forward Totalized Volume Flow
Reverse Totalized Volume Flow
Forward Totalized Mass Flow
Reverse Totalized Mass Flow
Chapter 1. Programming Site Data
Global-System
window earlier in