Electronic
boards over
temperature
(t>95°c) in
cooking
modes.
F12
Electronic
boards over
temperature in
a double oven,
(t>105°c) to
stop only the
lower one
when the upper
is running in
self-clean.
Meat probe
error
F13
Communication
F14
problem among
the electronic
BWOS 30100 SERVICE MANUAL
connection
Defective
circuit on
display board.
Overheating of
Cooling fan
the internal
broken
parts.
Bad
connections
between
cooling fan
and
electronics.
Air flow
through the
cooling
channel is not
sufficient.
Defective
cooling fan
relay on main
power board
Faulty ntc
sensor on
main power
board
Overheating of
The control
the internal
has detected
parts.
too much heat
and prevents
the user from
using both
cavities
together.
The meat
P6 connector
probe option is
on the main
not available in
power board
standard
has a
series.
configuration
jumper
replacing the
meat probe
input wires.
Problem on
Bad
the i2c
connections
communication
35
eventually
replace cable.
Replace display
7.19
board
Replace the
7.2
cooling fan
Check
connections
Check proper
installation. The
slot between the
control panel
and the door
must be free.
Replace the
main power
7.17
board.
Replace the
main power
7.17
board.
Wait for the
oven cools
down
Be sure that the
jumper is
properly
connected
Check and
eventually
replace one of
--
--
--
--