Over
temperature
F05
detected while
cooking
(t>650°f)
F06
Lower
Oven
Over
F07
temperature
detected in
self-clean
(t>950°f)
F08
Lower
Oven
Possible short
circuit on
display board
micro pins
F09
Possible short
circuit on
display board
circuits
F10
Display board
eeprom data
F11
BWOS 30100 SERVICE MANUAL
Runaway
One or more
temperature
relays are
condition
stuck, driving
during
heating
cooking.
elements.
Check the
contact of
relay
Runaway
One or more
temperature
relays are
condition
stuck, driving
during self-
heating
clean.
elements.
Check the
contact of
relay
Hardware
Humidity may
failure.
have created
condensation
on the
circuits.
Short circuit
on display
board.
Hardware
Humidity may
failure.
have created
condensation
on the
circuits.
Short circuit
on display
board
connectors.
Short circuit
on display
board.
Memory empty First power up
or new board
installed.
Memory
Bad memory
cannot be
or circuit on
accessed
board.
Bad cable
34
Replace the
power board
7.17
Replace the
power board
7.17
Remove power
and dry the
board.
Replace the
7.19
display board.
Remove power
and dry the
board.
Check
connectors and
eventually clean
or replace the
board to board
cables.
Replace the
7.19
display board.
Configure the
oven model.
2.5
(resistor
2.6
configuration +
manual test)
Replace power
7.17
board
Check and
--
--
--
--