Starting The Site Maintenance Terminal; Setting The Ip Address Of The Site Maintenance Terminal Pc - Huawei BTS3900 GSM Commissioning Manual

Hide thumbs Also See for BTS3900 GSM:
Table of Contents

Advertisement

5 Commissioning the BTS (Transmission Unavailable)

5.1 Starting the Site Maintenance Terminal

This describes how to start the SMT. To start the SMT, you need to set the IP address of the
SMT PC, connect the SMT PC to the BTS, and then log in to the SMT.

5.1.1 Setting the IP Address of the Site Maintenance Terminal PC

This describes how to set the IP address of the SMT PC to the same network segment as the IP
address (192.168.0.72/255.255.255.0) of the BTS.
5.1.2 Locally Connecting the SMT PC to the BTS
This describes how to connect the Site Maintenance Terminal (SMT) PC to the ETH port on the
main control module of the BTS through an Ethernet cable. After they are connected, you can
operate and maintain the BTS on the SMT.
5.1.3 Logging in to the BTS at the Local End
This describes how to log in to the BTS. You can run the SMT to directly log in to the BTS at
the local end.
5.1.1 Setting the IP Address of the Site Maintenance Terminal PC
This describes how to set the IP address of the SMT PC to the same network segment as the IP
address (192.168.0.72/255.255.255.0) of the BTS.
Prerequisite
The TCP/IP protocol is installed on the SMT PC.
Procedure
Step 1 To set the IP address of the PC, perform the following steps where the Windows XP operating
system is taken as an example: On Windows XP, choose Start > Setting > Control Panel .
Step 2 Double-click Network Connections in the displayed Control Panel window. Right-click Local
Area Connection in the displayed dialog box.
Step 3 Choose Properties from the shortcut menu. The Local Area Connection Properties dialog
box is displayed.
Step 4 Select Internet Protocol (TCP/IP), and click Properties. The Internet Protocol (TCP/IP)
Properties dialog box is displayed.
Step 5 Select Use the following IP address.
Step 6 Enter the correct IP address, subnet mask, and default gateway. Ensure that the IP address of the
SMT PC is in the same network segment as the IP addresses (192.168.0.72/255.255.255.0) of
the BTS so that a maintenance channel on the BTS side can be established.
Step 7 Click OK to complete the settings.
----End
5-2
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
BTS3900(A) GSM
Commissioning Guide
Issue 02 (2009-04-20)

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Bts3900a gsmV300r008

Table of Contents