Figure 4-28 Query Board Information Dialog Box - Huawei BTS3900 GSM Commissioning Manual

Hide thumbs Also See for BTS3900 GSM:
Table of Contents

Advertisement

4 Commissioning the BTS (Transmission Available)
4-32
Panel tab page and choose Query Board Information. The Query Board
Information dialog box is displayed.
(2) Click the Running Parameter tab, and then click Query on the Running
Parameter tab. The query is successful, and the running status of the board is
displayed in the dialog box. The current Environment Temperature is
28.0℃, as shown in

Figure 4-28 Query Board Information dialog box

2.
On the LMT, set the High Temperature Alarm Threshold to a value lower than the
normal temperature to trigger the alarm.
(1) In the BSC6000 Local Maintenance Terminal window, right-click the site to
be queried and choose Configure Site Board Attributes. The Configure Site
Board Attributes dialog box is displayed.
(2) Click Configure Site Board Attributes, the Site Device Attributes dialog box
is displayed.
(3) Right-click DTCU and choose Configure Site Board Attributes. The Basic
Attributes of Site Board dialog box is displayed.
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Figure
4-28.
BTS3900(A) GSM
Commissioning Guide
Issue 02 (2009-04-20)