Nokia Alcatel-Lucent OXO Connect Series Installation Manual page 66

Advertisement

Chapter
4
X0
X1
XJ3 jumper position depends on 12V input source
3. Push the power supply module back into the cabinet and secure it in place with a screwdriver.
4. Now on the external battery unit:
a. Ensure that the 12V stack battery unit has been properly prepared (as above).
b. Ensure that the ON/OFF switch is set to the OFF position (O or black).
c. Connect the J1 jack from the external battery unit to the OXO Connect Compact platform.
d. Ensure that the mains power cable is connected to the external battery unit, plug this cable into
the mains supply and check that the green LED on the unit is illuminated.
e. Set the ON/OFF switch to the ON position (I or red).
5. Restart the system.
6. Leave the batteries to charge for at least one hour.
7. Test the autonomy of the system by disconnecting the external battery unit from the mains supply
for one minute. During this time, check that the system is still powered.
4.3.4 Connecting a UPS
Note:
This paragraph is not relevant to the OXO Connect Compact platform.
A UPS (Uninterruptible Power Supply) can be used to allow system data to be saved for at least an
hour in the event of mains failure.
to Mains
It is connected via the mains socket at the rear of the platform:
UPS Power: use the mains cable provided with the OXO Connect module.
UPS Connection - module: use the cable supplied with the UPS
For an installation using 3 OXO Connect modules, 2 UPSs are required: one feeds two of the modules,
the other feeds the third module.
8AL91217USAA - Ed. 01 - July 2018 - Installation Manual
Powering and connecting the PBX to the customer LAN
X3
MGE UPS
ellipse
300
SYSTEMS
UPS
X2
66/216