Download Print this page

Nokia Alcatel-Lucent OXO Connect Series Installation Manual page 158

Advertisement

8
Chapter
INTERIOR COV-
ERAGE
EXTERNAL COV-
ERAGE
8.10.1.5 Interactions
Interactions with other features
IBS DECT and IBS PWT (Personal Wireless Telecommunications) cannot run together on the same
system. The first IBS plugged determines the system type (DECT or PWT).
To switch from one system to another, unplug all IBSs, make a warm restart and plug in the IBSs.
Interactions with other applications
IBSs are fully compatible with other wireless technologies such as VOWLAN.
Interactions with other software releases
OXO Connect release 5.1 requires 4 kinds of DECT initialization: Europe, Latin America, United-States
and China. See also:
8.10.1.6 Limits
Number of IBSs: 20 IBSs per cabinet is recommended, however, the number of IBSs is only restricted
by the available power.
DECT link limit: 3 links on an IBS with one UA access, 6 links on an IBS with 2 UA accesses.
DECT handset limit: up to 120 handsets on a system.
8.10.1.7 Performance and quality
IBSs are downloaded during the system start phase or when hot plugged. A system with many IBSs
plugged might take longer to complete the start phase.
Downloading 1 IBS takes about 30 seconds. It takes more time when several IBSs are plugged on the
same UA resource.
The end of restart is only possible after all the devices have been taken into account.
If an IBS downloading fails, the IBS restarts with the previously installed software.
8AL91217USAA - Ed. 01 - July 2018 - Installation Manual
Device commissioning
Recommendations for location
As far as possible from walls
Do not fix directly to a metallic structure
Do not place in false ceilings or in telecom
rooms
As far as possible from industrial machines
or electrical cabinets
Place the base stations in an open space
(as far as possible from buildings)
Place the base stations higher than low ob-
stacles (trees, cars etc.)
IBS configuration
on page 159.
Possible solutions
Suspend Alcatel-Lucent 4070 IO/EO in a
clear zone
Move Alcatel-Lucent 4070 IO/EO into an-
other zone
Place Alcatel-Lucent 4070 IO/EO in useful
zones (corridors)
Place 4070 IO/EO in useful zones
Attached to pylons for example
At the top of buildings on pylons for exam-
ple
158/216

Advertisement

loading