Nokia Alcatel-Lucent OXO Connect Series Installation Manual page 206

Advertisement

Chapter
11
On a cold reset, all PRESENT boards are taken into account (irrespective of whether they are
ACCEPTED or REFUSED)
A board which is PRESENT on a cold reset can later be determined as ABSENT on a warm reset if
in the meantime the board has been unplugged or there has been a board detection failure
After a cold or warm reset, new boards are always taken into account and declared as PRESENT
(and then ACCEPTED or REFUSED)
The following table describes situations more specifically relevant to plugging/unplugging boards.
Situation
A board is plugged into a slot never before oc-
cupied
A board is replaced with another board of the
same type
A board is replaced with another board of a dif-
ferent type
A PRESENT and ACCEPTED board is unplug-
ged
A PRESENT and REFUSED board is unplug-
ged
11.6.1 Adding a board into a vacant slot
The following procedure assumes that a board is to be installed in a vacant slot in the system cabinet.
Note:
Hot installation is forbidden in OXO Connect Compact platforms and for PowerCPU EE C25 boards. It is
also forbidden for PowerCPU EE boards in all platforms.
1. If a hot installation is not possible, stop the system and disconnect it from the mains power supply
2. Locate the required vacant slot in the cabinet and remove the metal plate for this slot
3. Taking anti-static precautions (for example, by wearing a grounded wrist strap), pick up the new
board and plug it into the vacant slot
4. Secure the end-plate of the board to the cabinet with the screw provided
5. If you have stopped and powered down the system, reconnect it to the mains power supply and
restart it
6. Perform any configuration and/or tests required for the new board
Note:
Following configuration in the OMC tool, you may be required to perform a warm reset of the system for the
configuration changes to take effect. In this case, the software will prompt you to perform the warm reset.
8AL91217USAA - Ed. 01 - July 2018 - Installation Manual
Maintenance level 1
Description
The board is detected as PRESENT and then deter-
mined to be ACCEPTED or REFUSED (according to
configuration criteria, such as authorized positions
and maximum hardware capacity). If the board is ac-
cepted, its accesses are taken into account depend-
ing on the system dimensioning criteria.
As above, except when the replacement board is
plugged in, configuration data for the previous board
is cleared.
The board's disappearance is detected and the
board is considered as out of order and then AB-
SENT. However, configuration data associated with
the unplugged board remains available.
The board's disappearance is detected and the
board is considered as ABSENT. However, configu-
ration data associated with the unplugged board re-
mains available.
206/216