4.2.8.6 Connecting a Doorphone
2 doorphone types are available, depending on the operating mode used:
Type A: relay-controlled doorphones (e.g. NPTT)
Type B: doorphones controlled by MF Q23 signals requiring a SLI interface (e.g. TELEMINI and
UNIVERSAL DOORPHONE)
The doorphone interface comprises an intercom and an optional latch powered by the mains supply
through a SELV (Safety Extra Low Voltage) transformer.
It is connected via the DOORPHA and DOORPHB outputs (control contacts open when idle) of the
DOORPHONE connector.
4.2.8.6.1 Connecting a NPTT Doorphone
DoorPhA1
DoorPhA2
DOORPHONE
DoorPhB1
To door
lock keeper
DoorPhB2
A single doorphone with doorstrike may be connected to the system.
The system also allows for the connection of 2 doorphones without latch.
4.2.8.6.2 Connecting a Telemini and Universal Doorphone
These doorphones require the use of a Z station interface.
Several of these doorphones can be connected to the system; the limit is determined by the
maximum number of analog stations the system can support.
8AL91217USAA - Ed. 01 - July 2018 - Installation Manual
Powering and connecting the PBX to the customer LAN
Distribution panel
220V
A
SLI1/2 &
BUSINESS PROCESSING UNIT
LAN
AUX
CONFIG.
MODULE 1
AUDIO
DOORPHONE
MODULE 2
ISDN T0 1
ISDN T0 2
ANALOG INTERFACES
9
10
11
12
13
1
2
3
4
5
PowerCPU EE
LAN
FAN
POWER
Mini-MIX
CPU
MODULE
SLI16-2
14
15
16
6
7
8
52/216