SIP registration KO
Set unregistered
SIP registration OK
8.2 8008/8018 DeskPhones
8.2.1 Commissioning
8.2.1.1 Connecting the set
To connect the set to the PBX:
1. Plug the RJ45 cable into the set LAN connector
2. Connect the RJ45 cable to the LAN itself
3. If your set is not powered by PoE, plug the AC/DC external adapter to the set power supply
connector and connect the plug to the power supply
Once the set is connected and powered up, it automatically starts initializing.
8.2.1.2 Set initialization
By default, 8008 DeskPhone and 8018 DeskPhone sets initialize dynamically and retrieve IP
information automatically.
You can change this initialization mode. Static initialization is mandatory when the system does not use
a DHCP server.
To switch from dynamic initialization to static initialization and modify IP parameters:
1. Wait for the set to initialize and reach the end of the Network setup process, displayed on screen
2. Press simultaneously the star and pound keys
This displays IP settings
3. Use the soft key next to an option to modify the selection
4. Validate your modifications with the soft key next to the tick symbol
8.2.1.2.1 Requested IP parameters
The following information must be provided for static initialization:
IP address (set's address)
Subnetwork mask
Router address
TFTP1 server address: OXO Connect IP address
Use VLAN: this box must be checked to enter a VLAN number
VLAN number if necessary
TFTP port
The TFTP address(es) to enter may differ according to system configuration.
Please contact your system administrator for details on the configuration of your system.
With dynamic initialization, IP parameters are automatically sent by a DHCP server to the phone.