Mitsubishi Electric MELSEC iQ-R Series User Manual page 535

Serial communication module
Hide thumbs Also See for MELSEC iQ-R Series:
Table of Contents

Advertisement

■Data example
The following table shows send data when a packet consists of [Header], [Conversion variable], [Terminator] and data stored
in the data storage area is D0=837 (0345H), D1=18 (0012H). (Reference: 120345H =1180485 in decimal form)
• Data example 1
Item
Fixed number of data/Variable
number of data
Number of Send Data
Start address of data storage area
Conversion unit
Conversion
Number of Send Digits of Data
Blank-padded character
Sign
Sign character
Number of decimals
Delimiter
*1
Send data
*1 The "_" indicates a space.
• Data example 2
Item
Fixed number of data/Variable
number of data
Number of Send Data
Start address of data storage area
Conversion unit
Conversion
Number of Send Digits of Data
Blank-padded character
Sign
Sign character
Number of decimals
Delimiter
*1
Send data
*1 '_' indicates a blank.
Setting contents
Fixed number of data
1
D0
Word
HEX  ASCII decimal
5
0
Unsigned
(Not applicable)
No decimal point
No delimiter
[Header]00837[Terminator]
Setting contents
Fixed number of data
1
D0
Double word
HEX  ASCII decimal
10
0
Signed
+
8
No delimiter
[Header]+00.01180485[Terminator]
Appendix 5 Operation Image and Data Structure of Predefined Protocol
Fixed number of data
1
D0
Word
HEX  ASCII decimal
5
Space
Signed
+
2
Comma
[Header]+_ _ 8.37, [Terminator]
Fixed number of data
2
D0
Word
HEX  ASCII decimal
5
Space
Unsigned
(Not applicable)
No decimal point
No delimiter
[Header]_ _ 837 _ _ _18[Terminator]
Fixed number of data
1
D0
Word
HEX  ASCII decimal
Variable number of digits
(Not applicable)
Signed
+
No decimal point
Comma
[Header]+837, [Terminator]
Fixed number of data
2
D0
Word
HEX  ASCII decimal
5
0
Signed
+
2
Comma
[Header]+008.37, +000.18[Terminator]
APPENDICES APPENDIX
A
533

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents