Troubleshooting - Toro e-Dingo 500 Operator's Manual

Compact tool carrier
Hide thumbs Also See for e-Dingo 500:
Table of Contents

Advertisement

Troubleshooting

Machine Troubleshooting
Problem
The machine does not drive.
When at rest, the loader arms lower more
than 7.6 cm (3 inches) per hour (less than
7.6 cm or 3 inches an hour is normal for
the machine).
When at rest, the loader arms lower 5 cm
(2 inches) quickly and then stop.
The machine does not charge.
Battery-Charger Error Codes
Problem
Code E-0-0-1, or E-0-4-7
Code E-0-0-4
Code E-0-0-7
Code E-0-1-2
Code E-0-2-3
Code E-0-2-4
Code E-0-2-5
Possible Cause
1. The parking brake is engaged.
2. The hydraulic-fluid level is low.
3. The hydraulic system is damaged.
1. The valve spool is leaking.
1. The cylinder seals are leaking.
1. The temperature is above 60°C (113°F)
or below -5°C (23°F).
Possible Cause
1. Battery high voltage
1. BMS or battery fault detected
1. Battery amp hour limit exceeded
1. Reverse polarity error
1. High AC voltage error (>270VAC)
1. Charger failed to initialize
1. Low AC voltage oscillation error
37
Corrective Action
1. Disengage the parking brake.
2. Add hydraulic fluid to the reservoir.
3. Contact your Authorized Service
Dealer.
1. Contact your Authorized Service
Dealer.
1. Replace the seals.
1. Charge the machine in conditions
between -5°C (23°F) and 60°C (113°F).
Corrective Action
1. Ensure that the battery voltage is
correct and the cable connections are
secure; ensure that the battery is in
good condition.
1. Contact an Authorized Toro Dealer.
1. Possible causes include poor battery
health, very deeply discharged battery,
poorly connected battery, and/or
high parasitic loads on battery while
charging. Possible solutions: Replace
batteries. Disconnect parasitic loads.
This error will clear once the charger is
reset by cycling DC.
1. The battery is connected to the charger
incorrectly. Ensure that the battery
connections are secure.
1. Connect charger to an AC source that
provides stable AC between 85 - 270
VAC / 45-65 Hz.
1. The charger has failed to turn on
properly. Disconnect the AC input and
battery connection for 30 seconds
before retrying.
1. The AC source is unstable. Could
be caused by undersized generator
or severely undersized input cables.
Connect charger to an AC source that
provides stable AC between 85 - 270
VAC / 45-65 Hz.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

2221822218g

Table of Contents