Configuring with Web Based Management
6.4 "Information" menu
● PROFINET AR Status
Shows the PROFINET application relation status.
– Online
– Offline
● Power Line 1 / Power Line 2 / Power over Ethernet
Status of the power supplies 1 and 2 or power over Ethernet. The power line 2 and Power
over Ethernet are only displayed if they are supported by the hardware. You will find further
information on this in the operating instructions.
● PLUG Configuration
Shows the status of the configuration data on the PLUG, refer to the section "System >
PLUG > PLUG Configuration".
● PLUG License
Shows the status of the license on the PLUG, refer to the section "System > PLUG > PLUG
License".
● Fault Status
Shows the fault status of the device.
● Remote Capture
Shows whether or not the function is enabled.
Buttons you require often
The pages of the WBM contain the following standard buttons:
● Refresh the display with "Refresh"
Web Based Management pages that display current parameters have a "Refresh" button at
the bottom edge of the page. Click this button to request up-to-date information from the
device for the current page.
Note
If you click the "Refresh" button, before you have transferred your configuration changes to
the device using the "Set Values" button, your changes will be deleted and the previous
configuration will be loaded from the device and displayed here.
● Save entries with "Set Values"
Pages in which you can make configuration settings have a "Set Values" button at the lower
edge. The button only becomes active if you change at least one value on the page. Click
this button to save the configuration data you have entered on the device. Once you have
saved, the button becomes inactive again.
Note
Changing configuration data is possible only with the "admin" login.
88
There is a connection to a PROFINET controller. The PROFINET controller has
downloaded its configuration data to the device. The device can send status data to the
PROFINET controller.
In this status, the parameters set by the PROFINET controller cannot be configured on
the device.
There is no connection to a PROFINET controller.
SCALANCE W1780/W1740 according to IEEE 802.11ac Web Based Management
Configuration Manual, 11/2019, C79000-G8976-C485-03