Requirement:
To adapt network parameters, DCP requires write access to the device. If access is write-
protected, the network parameters cannot be configured.
On the SCALANCE devices you configure the access in "System > Configuration".
Description
The page contains the following boxes:
● Interface
Select the required interface.
● Discover
Starts the search for devices reachable via the selected interface.
On completion of the search the reachable devices are listed in the table. The table is limited
to 100 entries.
The table has the following columns:
● Port
Shows the port via which the device can be reached.
● MAC Address
Shows the MAC address of the device.
● Device Type
Shows the product line or product group to which the device belongs.
● Device Name
If the device supports this function, you can assign a new PROFINET device name to the
device.
● IP Address
If necessary, adapt the IPv4 address of the device.
The IPv4 address should be unique within your network and should match the network. The
IPv4 address 0.0.0.0 means that no IPv4 address has yet been set.