Siemens SCALANCE W1780 Configuration Manual page 255

Industrial wireless lan
Table of Contents

Advertisement

Communication
In normal operation, the access point is used as an interface to a network and communicates
with clients. There are, however, situations in which several access points need to
communicate with each other, for example to extend wireless coverage or to set up a wireless
backbone. This mode is possible with WDS (Wireless Distributed System).
Description
The table has the following columns:
● Radio
Shows the available WLAN interfaces.
● Port
Shows the WDS interfaces.
● Port enabled
Enables the WDS interface.
● Connection over
Specify the VAP interface via which the WDS connection is established. Both the MAC
address of the VAP and the security settings, e.g. WPA2, are used.
SCALANCE W1780/W1740 according to IEEE 802.11ac Web Based Management
Configuration Manual, 11/2019, C79000-G8976-C485-03
Configuring with Web Based Management
6.6 "Interfaces" menu