● Test
With this button, you can test whether or not the specified RADIUS server is available. The
test is performed once and not repeated cyclically.
● Test Result
Shows whether or not the RADIUS server is available:
– Not reachable
– Reachable, key not accepted
– Reachable, key accepted
Steps in configuration
Entering a new server
1. Click the "Create" button. A new entry is generated in the table.
The following default values are entered in the table:
– RADIUS Server Address: 0.0.0.0
– Server Port: 1812
– Max. Retrans.: 3
– Primary server: No
2. In the relevant row, enter the following data in the input boxes:
– RADIUS Server Address
– Server Port
– Shared Secret
– Shared Secret Conf
– Max. Retrans.: 3
– Primary server: No
3. If necessary check the reachability of the RADIUS server.
4. Click the "Set Values" button.
Repeat this procedure for every server you want to enter.
SCALANCE W1780/W1740 according to IEEE 802.11ac Web Based Management
Configuration Manual, 11/2019, C79000-G8976-C485-03
The IP address is not reachable.
The IP address is reachable, the RADIUS server is, however, not running.
The IP address is reachable, the RADIUS server does not, however accept the shared
secret.
The IP address is reachable, the RADIUS server accepts the specified shared secret.
Configuring with Web Based Management
6.10 "Security" menu
305