Configuring with Web Based Management
6.5 "System" menu
Description
The page contains the following boxes:
● SNMP
Select the SNMP protocol from the drop-down list. The following settings are possible:
– "-" (disabled)
– SNMPv1/v2c/v3
– SNMPv3
● SNMPv1/v2c Read-Only
If you enable this option, SNMPv1/v2c can only read the SNMP variables.
Note
Community String
For security reasons, do not use the standard values "public" or "private". Change the
community strings following the initial installation.
The recommended minimum length for community strings is 6 characters.
For security reasons, only limited access to objects of the SNMPCommunityMIB is possible
with the SNMPv1/v2c Read Community String. With the SNMPv1/v2c Read/Write
Community String, you have full access to the SNMPCommunityMIB.
● SNMPv1/v2c Read Community String
Enter the community string for read access of the SNMP protocol.
● SNMPv1/v2c Read/Write Community String
Enter the community string for read and write access of the SNMP protocol.
● SNMPv1 Traps
Enable or disable the sending of SNMPv1 traps (alarm frames). On the "Trap" tab, specify
the IP addresses of the devices to which SNMPv1 traps will be sent.
● SNMPv1/v2c Trap Community String
Enter the community string for sending SNMPv1/v2c messages.
182
SNMP is disabled.
SNMPv1/v2c/v3 is supported.
Note
Note that SNMP in versions 1 and 2c does not have any security mechanisms.
Only SNMPv3 is supported.
SCALANCE W1780/W1740 according to IEEE 802.11ac Web Based Management
Configuration Manual, 11/2019, C79000-G8976-C485-03