Upkeep and maintenance
7.4 Restoring the factory settings
With the reset button
When pressing the button, make sure you observe the information in the "Reset button" section
in the operating instructions.
Follow the steps below to reset the device parameters to the factory settings:
1. Turn off the power to the device.
2. Loosen the screws of the cover.
3. Remove the cover.
4. Now press the Reset button and reconnect the power to the device while holding down the
button.
5. Hold down the button until the red fault LED (F) stops flashing after approximately 10
seconds and is permanently lit.
6. Now release the button and wait until the fault LED (F) goes off again.
7. The device then starts automatically with the factory settings.
With the Primary Setup Tool
Follow the steps below to reset the device parameters to the factory defaults with the Primary
Setup Tool.
1. Select the device whose parameters you want to reset.
2. Click on the menu item "Reset" in the "Module" tab.
3. Confirm the prompt with "OK".
Via the configuration
You will find detailed information on resetting the device parameters using the WBM and CLI
in the configuration manuals:
● Web Based Management, section "Restart (Page 149)"
● Command Line Interface, section "Reset and Defaults"
338
SCALANCE W1780/W1740 according to IEEE 802.11ac Web Based Management
Configuration Manual, 11/2019, C79000-G8976-C485-03