Supplying The System With Power - Siemens HiPath 3000 Series Service Documentation

Table of Contents

Advertisement

start_h3.fm
Starting Up HiPath 3000
Starting Up HiPath 3550, HiPath 3350, HiPath 3500, HiPath 3300
5.2.2

Supplying the System With Power

Caution (for Brazil only)
7
The use of the outlet strip with overvoltage protection with part number C39334-
Z7052-C33 is absolutely mandatory. The AC power of the system must be conduct-
ed through the outlet strip with overvoltage protection.
Procedure
Step
1.
Plug in the power supply cable and, where applicable, the battery cable.
Note (for Brazil only): The AC power of the HiPath 3550, HiPath 3350, HiPath
3500, and HiPath 3300 systems is internally equipped with transient overvoltage
protection up to approx. 2 kV. Since additional lightning protection is prescribed
for Brazil, the AC power of a system must be conducted through the outlet strip
with overvoltage protection (part number C39334-Z7052-C33). In this way, tran-
sient overvoltage protection is guaranteed up to approx. 4 kV.
2.
Monitor the Run LED of the central controller. The individual steps of the system
boot (Table 5-6) can be observed this way.
RUN LED HiPath 3550, HiPath 3350, HiPath 3500, HiPath 3300
The central board has a RUN LED that indicates the system status.
Table 5-6
RUN LED - LED Status Meaning
RUN LED
Off
On
Off
On
Off
for 0.1 s
Flashing
0.5 s on/0.5 s off
Flashing
0.1 s on/0.1 s off
1
The flashing rhythm depends on the load. The higher the system load the slower the flashing rhythm.
5-12
No power
Reset switch pressed briefly
Reset switch held down for more than 5 seconds (LED is extinguished
to acknowledge that a reload has begun)
System boot
Load operation: APS in SDRAM, loadware, and card data
Normal operating state (zero load)
MMC removed or defective
Activity
Meaning
1
A31003-H3590-S100-7-7620, 06/2012
HiPath 3000/5000 V9, Service documentation
Nur für den internen Gebrauch