Siemens HiPath 3000 Series Service Documentation page 1063

Table of Contents

Advertisement

Nur für den internen Gebrauch
Table 12-8
Event Viewer Entries for the HiPath 5000 Server
Event
De-
Error
fault
trap
1014
X
File open
error
1015
X
Error
while set-
sockopt.
1016
X
Error
while
recvfrom.
1017
X
Error
while
sending
to <IP-
Adr>
1018
X
Transfer
timed out
A31003-H3590-S100-7-7620, 06/2012
HiPath 3000/5000 V9, Service documentation
Meaning
text
Logical TFTP
error; HiPath
3000/5000 dis-
plays a mes-
sage indicating
that frame page
cannot be
opened
Server problem:
IP socket could
not be initialized
HiPath 3000/
5000 no longer
replies when
files are re-
ceived
Logical error
when sending
data to HiPath
3000/5000
No acknowl-
edgement re-
ceived/sent
User reaction
Wait 5 minutes then
repeat action.
Save event
Shut down and re-
file for er-
start server.
ror analy-
If error is still
sis
present, restart the
PC.
Save event
Connection error,
file for er-
HiPath 3000/5000
ror analy-
HIP problems.
sis
Check if ping is
working:
If ping is working:
wait 5 mins and re-
start server.
If ping is not work-
ing properly, check
if the "Ping unsuc-
cessful" error mes-
sage appears in the
Event Viewer.
Save event
Unrecoverable er-
file for er-
ror.
ror analy-
Restart server and
sis
report error to ap-
propriate service
support.
Save event
Possible connec-
file for er-
tion interruption or
ror analy-
HiPath 3000/5000
sis
HIP problems.
service.fm
Service
Guided Maintenance
Cate-
Source
gory
adm HiPath
AllServ
e
adm HiPath
AllServ
e
adm HiPath
AllServ
e
adm HiPath
AllServ
e
adm HiPath
AllServ
e
12-89

Hide quick links: