Siemens HiPath 3000 Series Service Documentation page 1041

Table of Contents

Advertisement

Nur für den internen Gebrauch
Table 12-7
HiPath 3000 Class B Error Messages
No.
HiPath 3000/
5000 Manager E:
Event Log Entry
09-061 !Overcurrent on
power controller
on (SLMO)
09-062 !Overcurrent on
power controller
off (SLMO
09-065 !Out of buffers for
card error on
09-066 !Out of buffers for
card error off
Error Class 11 – General Messages
11-058 !Too many L1 er-
rors
Error Class 12 – Processor Exceptions
12-000 Initial Stack Ptr
12-001 Initial Prg.
Counter
A31003-H3590-S100-7-7620, 06/2012
HiPath 3000/5000 V9, Service documentation
Meaning
Overcurrent on the
specified SLMO
board.
Overcurrent on the
specified SLMO
board has been
corrected.
Insufficient pool
capacity on the
specified SLMO
board.
Insufficient pool
capacity on the
specified SLMO
board has been
corrected.
Too many layer 1
errors.
Reset: Initial Stack
Pointer
Reset: Initial Pro-
gram Counter
Required Measures
Check the power and line
on the terminal and power
supply unit.
Replace hardware if nec-
essary.
None
Check lines and terminals.
Set up a default trace.
High traffic load: –>
Distribute load to sev-
eral boards.
Board is faulty: -> Re-
place board.
None
Check the lines, terminal,
and port.
A short circuit may have
occurred.
Create a trace.
Create a stack dump.
Save a snapshot.
Create a trace.
Create a stack dump.
Save a snapshot.
service.fm
Service
Guided Maintenance
Note
12-67

Hide quick links:

Advertisement

Table of Contents
loading