Siemens HiPath 3000 Series Service Documentation page 487

Table of Contents

Advertisement

Nur für den internen Gebrauch
Interfaces
from the CO
to the tele-
Figure 3-126
ALUM4 - Interfaces (S30817-Q935-A)
The cable that is plugged in by default is split and is connected to the TLA and to the
>
4/8/16SLA board.
ALUM module contact assignments
Table 3-173
ALUM4 - Interface Assignments (not for U.S.)
Contact
1
2
3
4
5
6
7
8
9
10
11
12
A31003-H3590-S100-7-7620, 06/2012
HiPath 3000/5000 V9, Service documentation
1
X3
9
...
8
...
8
X6
1
X4
8
Connector X3
R1 from trunk 1a
T1 from trunk 1b
R2 from trunk 2a
T2 from trunk 2b
R3 from trunk 3a
T3 from trunk 3b
R4 from trunk 4a
T4 from trunk 4b
16
1
ALUM module
Connector X4
AE1 to Stn. 1a
BE1 to Stn. 1b
AE2 to Stn. 2a
BE2 to Stn. 2b
AE3 to Stn. 3a
BE3 to Stn. 3b
AE4 to Stn. 4a
BE4 to Stn. 4b
Boards for HiPath 3000
CB side
X1
X2
Board side
Connector X6
AT1 to TLA a
BT1 to TLA b
AT2 to TLA a
BT2 to TLA b
AT3 to TLA a
BT3 to TLA b
AT4 to TLA a
BT4 to TLA b
TA4 to SLA* a
TB4 to SLA* b
TA3 to SLA* a
TB3 to SLA* b
boards.fm
Options
3-355

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents