Correcting Errors

12.5.1

Automatic Error Correction

One of the below recovery actions is assigned to each error in the error memory. These recov-
ery actions are programmed to automatically correct errors that occur.
Hard restart
Reload board
Reload CDB backup
Port lockout
Power failure transfer (loop start)
None
A watchdog activates continuous loops.
If no recovery measure is assigned or if the one that is assigned fails, a service technician has
to correct the error manually.
12.5.2

Manual Error Correction Without HiPath 3000/5000 Manager E

Manually activating a restart (reset)/reload
Pressing the reset button on the central control board of HiPath 3000
initiates a Reset (hard restart of the entire system with the current CDB) if the button is
pressed for less than 5 seconds. The RUN LED lights up when the Reset button is pressed.
initiates a Reload if the button is pressed longer than 5 seconds. The RUN LED disappears
after approximately 5 seconds as verification that the reload has been initiated. The entire
content of the customer database is replaced by its default version. All country and cus-
tomer-specific settings are lost.
If you initiated a system reload, the system must be reset after the CDB has been
>
installed. This ensures that all signaling gateways (= HG 1500 gatekeeper) are re-
set.