h3h5_in_the_lan.fm
HiPath 3000/5000 in the LAN Network
IP Trunking
Standard Numbering Plan
Telephone numbers are converted into the IP addresses of the remote communications plat-
form (HiPath 3000) within the LAN access (HG 1500). A "routing table" which assigns the cor-
rect IP address to each destination call number or destination node number must be created
to ensure that the IP address of the correct target node is implemented.
A network with either open or closed numbering should be configured for this purpose. When
using closed numbering, each station number in the network can have up to seven digits
whereas in open numbering, the node number + station number together must not exceed sev-
en digits.
Standard Compliance
Connection protocol
"Voice over IP" to ITU H.323
Voice transmission - Audio Codecs
ITU G.711
ITU G.723.1
ITU 6.729
Echo suppression
in accordance with ITU-T G.165
Prioritization of data – Quality of Service (QoS)
IEEE 802.1d
RFC2474 Differentiated Services (DiffServ)
RFC791 Type of Service (TOS)