Guided Maintenance
Table 12-7
HiPath 3000 Class B Error Messages
No.
HiPath 3000/
5000 Manager E:
Event Log Entry
20-042 !MMC-size
20-043 !CDR-MMC MMC
full
Error Class 21 – Device Handler Messages
21-000 !no dial tone de-
tected
21-001 !dial tone detect-
ed
21-007 !Clock ON
12-80
Meaning
Output of MMC
module size
Memory on the
MMC module or in
the HiPath 2000
file system is insuf-
ficient for creating
the advanced call
data memory.
No dial tone de-
tected.
Dial tone detected. None
ISDN clock found. None
Required Measures
None
Use headset to check dial
tone.
Replace port or terminal if
necessary.
A31003-H3590-S100-7-7620, 06/2012
HiPath 3000/5000 V9, Service documentation
Nur für den internen Gebrauch
Note
During system
startup, the size
of the MMC
module is read
out and hexa-
decimally output
in bytes 1 and 2
of the info bytes.
Value "00 10"
describes the
16-MB MMC,
value "00 40" de-
scribes the 64-
MB MMC.
This does not
apply to HiPath
2000.