Activating And Charging The Battery - Toro Greensmaster 3420 TriFlex Operator's Manual

Traction unit, 04540-serial no. 403099001 and up
Hide thumbs Also See for Greensmaster 3420 TriFlex:
Table of Contents

Advertisement

4
Activating and Charging
the Battery
No Parts Required
Procedure
Use only electrolyte (1.265 specific gravity) to fill the
battery initially.
WARNING
Battery terminals or metal tools could short
against metal machine components, causing
sparks. Sparks can cause the battery gasses
to explode, resulting in personal injury.
• When removing or installing the battery,
do not allow the battery terminals to touch
any metal parts of the machine.
• Do not allow metal tools to short between
the battery terminals and metal parts of the
machine.
1.
Remove the fasteners and battery clamp and
lift out the battery.
Important:
Do not add electrolyte while the
battery is in the machine. You could spill it,
causing corrosion.
2.
Clean the top of the battery and remove the vent
caps
(Figure
5).
3.
Carefully fill each cell with electrolyte until the
plates are covered with about 6 mm (1/4 inch)
of fluid
(Figure
6).
Figure 5
1. Electrolyte
4.
Allow approximately 20 to 30 minutes for the
electrolyte to soak into the plates. Fill as
necessary to bring the electrolyte to within about
6 mm (1/4 inch) of the bottom of the fill well
(Figure
6).
5.
Connect a 2 to 4 A battery charger to the battery
posts. Charge the battery for at least 2 hours at
4 A or for at least 4 hours at 2 A until the specific
gravity is 1.250 or higher and the temperature is
at least 16°C (60°F) with all cells gassing freely.
WARNING
Charging the battery produces gasses
that can explode.
Never smoke near the battery and keep
sparks and flames away from the battery.
Important:
for at least the time specified above, you may
reduce the life of the battery.
6.
When the battery is charged, disconnect the
charger from the electrical outlet and battery
posts.
Note:
After the battery has been activated,
add only distilled water to replace normal loss,
although maintenance-free batteries should not
require water under normal operating conditions.
Important:
battery may result in battery gassing and/or
premature battery failure.
7.
Install the vent caps.
g005080
8.
Place the battery on the battery tray and secure
it with the battery clamp and fasteners removed
previously.
9.
Install the positive cable (red) to the positive (+)
terminal and then the negative cable (black)
to the negative (–) terminal of the battery and
13
Figure 6
If you do not charge the battery
Failure to correctly activate the
g032705

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents