Maintenance Intervals; Filter Material; Enclosure Air Filter Replacement B3 - Ul (Nema) Type 12 Hinged Door Wall Mount Enclosures - ABB ACH580 Series Installation, Operation And Maintenance Manual

Hide thumbs Also See for ACH580 Series:
Table of Contents

Advertisement

150
Maintenance

Maintenance intervals

If installed in an appropriate environment, the drive requires very little maintenance.
This table lists the routine maintenance intervals recommended by ABB for ACH580
enclosures in addition to the intervals on page 81.
Maintenance
Check/replace hinged
door wall mount
enclosure inlet air filter
Enclosure air filter replacement B3 – UL (NEMA) Type 12 hinged door
wall mount enclosures

Filter material

Material
American Air Filter (358-35-06A-12A)
This procedure applies to drive with input disconnect configurations in UL (NEMA)
Type 12 hinged door wall mount enclosures. This filter is located at the bottom of the
enclosure. Use the following procedure to check and replace filters.
1. On the enclosure, remove the screws holding the filter bracket in place.
2. Remove the filter kit from the enclosure.
3. Lift the filter out of the filter bracket and replace as appropriate.
4. With the filter in the filter bracket, reinstall filter kit onto enclosure.
5. Replace the mounting screws. Tighten to the recommended torque of 2 N•m
(1.47 ft-lbs) per installation instruction 3AXD50000221370.
Diagnostics
Refer to the
ACH580-PCR/PDR
Configuration
Hinged door wall
mount UL (NEMA)
Type 12 enclosures
Back of
Enclosure
Mounting
Screws (4X)
Diagnostics
instructions on page 57.
ACH580 Installation, Operation and Maintenance Manual
Interval
Check every 3
months. Replace
as needed.
Filter Type
POLYKLEON WHITE 12.7mm (1/2 in.) X 152.4mm (6 in.) X
304.6mm (12 in.) stk.
Filter Bracket
Instruction
Enclosure air filter replacement
B3 – UL (NEMA) Type 12 hinged
door wall mount enclosures
page 150.
Enclosure Door
Bottom of Enclosure
on

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents