■Wiring diagram and parameter settings
Wire the electromagnetic contactors to safety remote I/O module as follows. For details on the terminal block, refer to the
following.
 CC-Link IE Field Network Remote I/O Module (With Safety Functions) User's Manual
Two-hand
operation switch
[1]
[3]
[2]
[4]
Above [1] to [4] are connected to the one with same numbers.
*1 Connect the two switches with normally open contact and normally closed contact between the input terminal and COM (+) terminal.
*2 Use two electromagnetic contactors operatable by 24VDC and 0.5A.
*3 Connect normally closed contact of the electromagnetic contactor between the input terminal and test pulse terminal.
5 SAFETY APPLICATION CONFIGURATION EXAMPLES
138
5.1 System Configured by a Safety CPU
24VDC
24VDC
[1]
[2]
*1
[3]
[4]
Electromagnetic
*2*3
contactor
L3
24VDC
L2
L1
Electromagnetic
*2*3
contactor
CCIEF remote (1)
NZ2GFSS2-32D
Network No.1
Station No.1
A1
+24V
A2
+24V
A3
24G
A4
24G
A5
FG
19
IO24V
20
IO24G
3
X2
4
X3
5
X4
6
X5
7
X6
8
X7
9
X8
10
X9
11
XA
12
XB
17
COM+
18
COM+
23
T0
24
T1
CCIEF remote (1)
NZ2EXSS2-8TE
Network No.1
Station No.1
19
IO24V
20
IO24G
1
Y0
2
COM-
3
Y1
4
COM-
Terminal block for power supply and FG (input)
A1
+24V
A2
+24V
A3
24G
A4
24G
A5
FG
Spring clamp terminal block (input)
Spring clamp terminal block (output)

Advertisement

Table of Contents
loading

Table of Contents