Operation with flammable gases

Observe the following points when operating a device with
flammable gases:
The device must be used in accordance with the
specifications in the relevant certificate.
Only the design with the IS 'Intrinsic Safety ' type of
protection may be operated with natural gas. The
pneumatic outputs must be vented in non-hazardous
areas.
During operation with flammable gases, the cover cap for
the air outlets must be removed and the air outlets tubed
separately. Both pipes must not be joined in one pipe.
The maximum ambient temperature must not up-scale
60 °C (140 °F).
See also Control Drawing 901305 on page 82.

Operation in areas with combustible dust

Observe the following points when operating a device with
combustible dust:
To prevent loss of type of protection, the housing must
not be opened.
Only use cable glands which are approved for the type of
protection and correspond to IP rating
Danger due to propagating brush discharge must be
avoided.

Operation in temperature class T6

During operation in temperature class T6, when the equipment
is partially or fully depressurized, ensure that there is no
possibility of an explosive atmosphere getting into the
pneumatic system or that any explosive atmosphere is removed
prior to compression by taking suitable action.
When commissioning in temperature class T6, flush the
pneumatic system by applying 1.4 (+/- 0.1) bar until all traces of
any explosive mixture have been removed, yet for at least
5 minutes. Ventilate and evacuate the EDP300 fully several times.

Temperature data

Note
Legibility of the display is guaranteed at an ambient
temperature of 20 to 70 °C. At 20 °C and lower, legibility can
become limited. Legibility can be compensated by adjusting
contrast. Contrast adjustment can be made manually directly on
the device.
The display can fail at temperatures below 20 °C. Moreover,
functioning of the device is guaranteed up to 40 °C.
FM
Temperature class
T1 to T4
T6
CSA
Temperature class
T4
T6
IP 6X.
11
Ambient temperature T
amb
40 °C to 85 °C
40 °C to 40 °C
Ambient temperature T
amb
40 °C to 85 °C