Parameters And Data Structures On A Fieldbus; Monitoring Data; Command Data - ABB UMC100.3 Manual

Univeral motor controller
Hide thumbs Also See for UMC100.3:
Table of Contents

Advertisement

U M C 1 0 0 . 3 U N I V E R S A L M O T O R C O N T R O L L E R T E C H N I C A L D E S C R I P T I O N
120

Parameters and Data Structures on a Fieldbus

In the following chapter you find a detailed description of all UMC parameters, the format of the command monitoring and diagno-
sis telegrams. Furthermore the information is provided of how the UMC data is mapped to the different communication interface.
The tables below represents the data allocation as realised with the built-in standard applications. It may differ for
customer-specific applications!

Monitoring Data

Word
Byte
Bit 7
0
Summary
Warning
1
UMC100 DI5 UMC100 DI4
0
1
2, 3
Motor Current in % of I
2
4, 5
Analogue Word (Thermal Load: 0% - 100%)
3
6, 7
Analogue Word (Time to trip in seconds)
Profile 1
4
8, 9
Analogue Word (Time to restart in seconds)
5
10.11
Analogue Word (Active power in selected scale)
12
DX1xx DI7
6
13
-
14
U Imbal.
warn
7
15
Earth fault
warning

Command Data

Word
Byte
Bit 7
0
-
0
1
UMC100
DO2
2
VI15x
Profile 1
DO0
1
3
-
2
4, 5
Analogue Word
3
6, 7
Analogue Word
4
8,9
Analogue Word
5
10,11
Analogue Word
1)
Not for Actuator 1 ... 4
Only for Actuator 1 ... 4
2)
Not for Overload Relay and Transparent
3)
4)
Only for Pole-Changing Starter
If start limit function is used
5)
Bit 6
Bit 5
Summary
Local Control
3
Fault
UMC100 DI3
(0% - 800%)
e
DX1xx
DX1xx
DI6
DI5
-
Run Time
Exceeded
2
U Imbal. trip
Undervoltage
warn
Earth fault
Cooling time
trip
running
Bit 6
Bit 5
Bit 4
Fault
Auto
Prepare
Reset
Mode
3
Emergency
Start
UMC100
UMC100
UMC100 24
DO1
DO0
V DC Out
-
-
-
-
-
-
Bit 4
Bit 3
Reverse
Overload
Lockout Time
3
warning
UMC100 DI2
UMC100 DI1
DX1xx
DX1xx
DI4
DI3
Out of
Torque Open
2
Position
2
Under-
Underpower
voltage trip
warn
-
THD warning
Bit 3
Bit 2
-
Run
Forward
1.3
/
Opening
2,3
-
-
DX1xx
DX1xx
DO3
DO2
-
-
Bit 2
Bit1
Bit 0
Run
Off
Run Reverse
3
Forward
1,3
/
/ Closing
Opening
2,3
UMC100 DI0
Run
-
Fast
Forward
4)
DX1xx
DX1xx
DX1xx
DI2
DI1
DI0
Torque
End Pos
End Pos
Closed
Open
Closed
2
2
Under-
Over-
Over-
power trip
power
power trip
warn
No start
1 start
More than 1
possible
left
start left
5)
5)
Bit1
Bit 0
Off
3
Run Reverse
/ Closing
1,3
Run
-
Fast
Forward
4)
DX1xx
DX1xx
DO1
DO0
-
-
1,3
2,3
Profile 2
2
5)
2,3
Profile 2

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents